Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00701

C00725

Parameter | Name:

C00701 | LA_NCtrl: digital connection list

Data type: UNSIGNED_16

Index: 23874

d

= 5D42

h

Connection parameters for "Actuating drive speed" application: Binary inputs

• Selection of the binary output signals for connection with the binary input signals

• The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the

subcodes.

Selection list
See

selection list - digital signals

Subcodes

Lenze setting

Info

C00701/1

0: Not connected

LA_NCtrl

: bCInh

C00701/2

15: DigIn_CInh

LA_NCtrl

: bFailReset

C00701/3

0: Not connected

LA_NCtrl

: bSetQuickstop

C00701/4

13: DigIn_bIn3

LA_NCtrl

: bSetDCBrake

C00701/5

14: DigIn_bIn4

LA_NCtrl

: bSetSpeedCcw

C00701/6

11: DigIn_bIn1

LA_NCtrl

: bJogSpeed1

C00701/7

12: DigIn_bIn2

LA_NCtrl

: bJogSpeed2

C00701/8

0: Not connected

LA_NCtrl

: bMPotUp

C00701/9

0: Not connected

LA_NCtrl

: bMPotDown

C00701/10

0: Not connected

LA_NCtrl

: bMPotInAct

C00701/11

0: Not connected

LA_NCtrl

: bMPotEnable

C00701/12

0: Not connected

LA_NCtrl

: bRFG_0

C00701/13

0: Not connected

LA_NCtrl

: bSetError1

C00701/14

0: Not connected

LA_NCtrl

: bSetError2

C00701/15

1: C_bTrue

LA_NCtrl

: bPIDInfluenceRamp

C00701/16

0: Not connected

LA_NCtrl

: bPIDIOff

C00701/17

1: C_bTrue

LA_NCtrl

: bRLQCw

C00701/18

0: Not connected

LA_NCtrl

: bRLQCcw

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00725 | Current switching frequency

Data type: UNSIGNED_8

Index: 23850

d

= 5D2A

h

As of version 03.00.00

Display of the current switching frequency

• When a variable switching frequency is selected in

C00018

, the switching frequency may change as a function

of the load and rotational frequency.

Selection list

(read only)

1 4 kHz var./drive-optimised
2 8 kHz var./drive-optimised
3 16 kHz var./drive-optimised
5 2 kHz constant/drive-optimised
6 4 kHz constant/drive-optimised
7 8 kHz constant/drive-optimised
8 16 kHz constant/drive-optimised

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1