Function library

10.3

L_PCTRL_1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C231/1

(Pos. Maximum)

C231/2

(Pos. Minimum)

C231/3

(Neg. Minimum)

C231/4

(Neg. Maximum)

0.0

%

199.9 Operating range

• Determination of the operating

range for the PID process control-

ler by limiting the input signal

nSet_a.

• Lenze setting: No limitation (-

199.9 % ... +199.9 %)

C242

Operating mode

0 Off

(Lenze setting)

The input setpoint nNSet_a is output

without any changes at the output

nOut_a.

1 Additive + feedforward control

nNSet_a and nAct_a are used as PID

input values. The arriving nNSet_a is

additively linked to the value output

by the PID element.

2 PID as setpoint generator.

nSet_a and nAct_a are used as PID in-

put values. The input nNSet_a is not

considered.

3 PID setpoint from

L_NSet_1

nNSet_a and nAct_a are used as PID

input values. The input nSet_a is not

considered.

C243

0.0

s

999.9 Influence acceleration time

• Acceleration time T

ir

for the influ-

encing factor.

• Lenze setting: 5.0 s

C244

0.0

s

999.9 Influence deceleration time

• Deceleration time T

if

for the influ-

encing factor.

• Lenze setting: 5.0 s

C245

-199.9

%

+199.9 Display of PID output value

nPIDOut_a

Parameter

Possible settings

Info