7.3

Setting parameters (short overview)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.5.6

PC

In this control mode, the control is executed via "free" parameters. The connection to inputs/out-

puts of the application takes place via the following system blocks:

Connection

Assignment

Connection

Assignment

RFR

LA_NCtrl.bFailReset

A1U

-

DI1

-

DI2

-

DI3

-

NO, COM

LA_NCtrl.bDriveFail

DI4

-

DO1

LA_NCtrl.bDriveReady

System block

Function

LS_DisFree

Any four 16-bit signals of the application can be displayed on display codes

LS_DisFree_a

Any four analog signals of the application can be displayed on display codes

LS_DisFree_b

Any eight digital signals of the application can be displayed on a bit-coded display

code

LS_ParFree_a

Output of 4 parameterisable analog signals

LS_ParFree_b

Output of 16 parameterisable digital signals

X101

NO

COM

GND

A1U

AR

RFR

DI1

DI2

DI3

DI4

24E

DO1

12I

X4

+

C472/1

C470/3

C470/4

C470/1

C470/2

Enable controller / reset error message

External supply 24 V DC

DriveFail

DriveReady

Speed setpoint

Selection of fixed setpoint 1/3

Selection of fixed setpoint 2/3

Manual DC-injection braking (DCB)

Direction of rotation CCw

Advertising