C00053 | dc-bus voltage, C00054 | motor current, C00056 | torque – Lenze 8400 BaseLine D User Manual

Page 181: C00057 | maximum torque, C00058 | output frequency, C053, C054, C058, C057, C056/2

Advertising
background image

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

181

9

Parameter reference

9.2

Parameter list | C00053

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00053

C00054

C00056

C00057

C00058

Parameter | Name:

C00053 | DC-bus voltage

Data type: UNSIGNED_16

Index: 24522

d

= 5FCA

h

Display of the current DC-bus voltage
Display range

(min. value | unit | max. value)

0

V

1000

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00054 | Motor current

Data type: UNSIGNED_16

Index: 24521

d

= 5FC9

h

Display of the current motor current/output current of the inverter
Display range

(min. value | unit | max. value)

0.00

A

300.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00056 | Torque

Data type: INTEGER_32

Index: 24519

d

= 5FC7

h

Display of the current torque
Display range

(min. value | unit | max. value)

-99.00

Nm

99.00

Subcodes

Info

C00056/1

Torque setpoint

• Only with sensorless vector control (

SLVC

).

C00056/2

Actual torque

• Estimated actual torque for all motor control modes.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00057 | Maximum torque

Data type: UNSIGNED_32

Index: 24518

d

= 5FC6

h

Display of the maximum torque to be generated by the motor

• The maximum torque to be generated by the motor depends on various factors, e.g. on Imax in motor mode

(

C00022

) and the motor type used.

Display range

(min. value | unit | max. value)

0.0

Nm

999.9

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00058 | Output frequency

Data type: INTEGER_32

Index: 24517

d

= 5FC5

h

Display of the current output frequency
Display range

(min. value | unit | max. value)

-655.0

Hz

655.0

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100