C00159 | cause for quick stop qsp, C00165 | error information, C00166 | error information text – Lenze 8400 BaseLine D User Manual

Page 195: C165, C159, Provides, Provides a, C166/1, Is use, C165/1

Advertising
background image

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

195

9

Parameter reference

9.2

Parameter list | C00159

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00159

C00165

C00166

Parameter | Name:

C00159 | Cause for quick stop QSP

Data type: UNSIGNED_16

Index: 24416

d

= 5F60

h

Bit-coded display of the cause/source of quick stop
Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 Terminal
Bit 1 Reserved
Bit 2 Reserved
Bit 3 Reserved
Bit 4 Application
Bit 5 Device command
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved

Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00165 | Error information

Data type: VISIBLE_STRING

Index: 24410

d

= 5F5A

h

Display of the error numbers divided into sectors in the case of an error
Subcodes

Info

C00165/1

Current error

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00166 | Error information text

Data type: VISIBLE_STRING

Index: 24409

d

= 5F59

h

Display of details of the currently pending error
Subcodes

Info

C00166/1

Resp. - current error

• Response of the currently pending error

C00166/2

Subj.area curr. error

• Subject area of the currently pending error

C00166/3

Mess.curr.error

• Textual message of the currently pending error

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT