Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

59

4

Device control (DCTRL)

4.2

Device states

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2.5

SwitchedON

In the "SwitchedOn" device state

• is the controller if the user has inhibited the controller (and no error is pending).
• I/O signalare evaluated.
• the monitoring modes are active.
• the controller can be parameterised.
• the application is basically executable.
• it can be changed to the "

OperationEnabled

" state by deactivating the controller inhibit.

Tip!

C158

provides a bit coded representation of all active sources/triggers of a controller inhi-

bit.

Depending on certain conditions, a state change takes place based on the "SwitchedOn" device sta-

te:

LED DRIVE READY

LED DRIVE ERROR

Display in

C137

Display in status word 1 (

C150

)

Bit 11

Bit 10

Bit 9

Bit 8

OFF

SwitchedON

0

1

0

0

Change condition

Changeover to the device state

Terminal RFR = HIGH level (controller enable)

OperationEnabled

Motor parameter identification requested.

MotorIdent

Undervoltage in the DC bus.

Trouble

/

Fault

(dependent on

C600/1

)

Error with error response "Trouble" occurs.

Trouble