C00517 | user menu, C00565 | resp. to mains phase failure, C517 – Lenze 8400 BaseLine D User Manual

Page 206: C565, 9parameter reference

Advertising
background image

9

Parameter reference

9.2

Parameter list | C00517

206

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00517

C00565

Parameter | Name:

C00517 | User menu

Data type: INTEGER_32

Index: 24058

d

= 5DFA

h

When a system is installed, parameters must be changed time and again until the system runs satisfactorily. The

user menu of a device serves to create a selection of frequently used parameters to be able to access and change

these parameters quickly.

• For setting "0" no entry is displayed in the user menu.

Setting range

(min. value | unit | max. value)

0

994

Subcodes

Lenze setting

Info

C00517/1

51

C00051

: Display of actual speed value

C00517/2

53

C00053

: Display of DC-bus voltage

C00517/3

54

C00054

: Display of motor current

C00517/4

61

C00061

: Display of heatsink temperature

C00517/5

137

C00137

: Display of device state

C00517/6

0

User menu: entry 6

C00517/7

0

User menu: entry 7

C00517/8

11

C00011

: Reference speed

C00517/9

39

C00039/1

: Fixed setpoint 1

C00039/2

: Fixed setpoint 2

C00039/3

: Fixed setpoint 3

C00517/10

0

User menu: entry 10

C00517/11

12

C00012

: Acceleration time main setpoint

C00517/12

13

C00013

: Deceleration time main setpoint

C00517/13

15

C00015

: V/f base frequency

C00517/14

16

C00016

: Vmin boost

C00517/15

22

C00022

: Imax in motor mode

C00517/16

120

C00120

: Motor overload threshold (I

2

xt)

C00517/17

87

C00087

: Rated motor speed

C00517/18

99

C00099

: Display of firmware version

C00517/19

0

User menu: entry 19

C00517/20

0

User menu: entry 20

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00565 | Resp. to mains phase failure

Data type: UNSIGNED_8

Index: 24010

d

= 5DCA

h

Response to the failure of mains phases
Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
4 WarningLocked

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising