3 "inhibit at power-on" auto-start option, Inhibit at power-on" auto-start option, 4device control (dctrl) – Lenze 8400 BaseLine D User Manual
Page 63
Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05
63
4
Device control (DCTRL)
4.3
"Inhibit at power-on" auto-start option
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.3
"Inhibit at power-on" auto-start option
In the Lenze setting
in
the auto-start option "Inhibit at power-on" is activated. This setting
prevents a change to the "
"state if the controller is already enabled at mains power-up.
The following three cases describe the controller behaviour as a function of controller enable and
set auto-start option. Here, we assume that no fault and trouble exist in the controller after power-
on.
Danger!
When the auto-start option "Inhibit at power-on" is deactivated, the motor can directly
start after power-on if the controller is enabled!