73

5

Motor control (MCTRL)

5.1

Motor selection/Motor data

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

How to carry out automatic motor parameter identification:

1. Inhibit the controller if it is enabled, e.g. via the

C002/16

device command or a LOW signal

at the X4/RFR terminal.

2. Wait until the drive is at standstill.
3. Transfer the nameplate data to the following codes:

C081

: Rated motor power

C087

: Rated motor speed

C088

: Rated motor current (according to the connection method /)

C089

: Rated motor frequency (according to the connection method /)

C090

: Rated motor voltage (according to the connection method /)

C091

: Motor cos ϕ

4. Start motor parameter identification via the

C002/23

device command.

5. Enable the controller again.

• Motor parameter identification starts.
• The progress of the identification can be seen in

C002/23

.

• The identification is completed if the "0: Off / ready" message is displayed in

C002/23

.

6. Inhibit controller again.