C00182 | s-ramp time pt1, C00200 | firmware product type, C00201 | firmware compile date – Lenze 8400 BaseLine D User Manual

Page 198: C00203 | product type code, C00222 | l_pctrl_1: vp, C222, C182, C00182, 9parameter reference

Advertising
background image

9

Parameter reference

9.2

Parameter list | C00182

198

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00182

C00200

C00201

C00203

C00222

Parameter | Name:

C00182 | S-ramp time PT1

Data type: INTEGER_16

Index: 24393

d

= 5F49

h

FB

L_NSet_1

: PT1 S-ramp time for the main setpoint ramp function generator

• Only effective with activated ramp smoothing (

C00134

= "1").

Setting range

(min. value | unit | max. value)

Lenze setting

0.01

s

50.00 20.00 s

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00200 | Firmware product type

Data type: VISIBLE_STRING

Index: 24375

d

= 5F37

h

Display of the firmware product type

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00201 | Firmware compile date

Data type: VISIBLE_STRING

Index: 24374

d

= 5F36

h

Display of the firmware compilation date

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00203 | Product type code

Data type: VISIBLE_STRING

Index: 24372

d

= 5F34

h

As of version 03.00.00

Display of the single device component types
Subcodes

Info

C00203/1

Reserved

C00203/2

Reserved

C00203/3

Reserved

C00203/4

Type: I/O micro

C00203/5

Type: Memory module

C00203/6

Type: Safety module

C00203/7

Reserved

C00203/8

Type: Complete device

C00203/9

Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00222 | L_PCTRL_1: Vp

Data type: INTEGER_16

Index: 24353

d

= 5F21

h

As of version 03.00.00

FB

L_PCTRL_1

: Gain factor Vp for the PID process controller

Setting range

(min. value | unit | max. value)

Lenze setting

0.1

500.0 1.0

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10