C00087 | rated motor speed, C00088 | rated motor current, C00089 | rated motor frequency – Lenze 8400 BaseLine D User Manual

Page 184: C00090 | rated motor voltage, C088, C089, C090, C087, Acco, C00089

Advertising
background image

9

Parameter reference

9.2

Parameter list | C00087

184

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00087

C00088

C00089

C00090

Parameter | Name:

C00087 | Rated motor speed

Data type: UNSIGNED_16

Index: 24488

d

= 5FA8

h

This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor

catalogue, the suitable value can be entered automatically.

Note:

It is mandatory to give the rated motor speed for the sensorless vector control (

SLVC

).

Setting range

(min. value | unit | max. value)

Lenze setting

50

rpm

9999 1460 rpm

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00088 | Rated motor current

Data type: UNSIGNED_16

Index: 24487

d

= 5FA7

h

This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor

catalogue, the suitable value can be entered automatically.
Setting range

(min. value | unit | max. value)

Lenze setting

0.00

A

99.00 21.00 A

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00089 | Rated motor frequency

Data type: UNSIGNED_16

Index: 24486

d

= 5FA6

h

This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor

catalogue, the suitable value can be entered automatically.

Note:

It is mandatory to give the rated motor frequency for the sensorless vector control (

SLVC

).

Setting range

(min. value | unit | max. value)

Lenze setting

10

Hz

1000 50 Hz

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00090 | Rated motor voltage

Data type: UNSIGNED_16

Index: 24485

d

= 5FA5

h

This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor

catalogue, the suitable value can be entered automatically.
Setting range

(min. value | unit | max. value)

Lenze setting

0

V

1000 400 V

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1