5 ls_analoginput, Ls_analoginput, 10 function library – Lenze 8400 BaseLine D User Manual

Page 240

Advertising
background image

10

Function library

10.5

LS_AnalogInput

240

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10.5

LS_AnalogInput

The LS_AnalogInput system block displays the analog input in the application on I/O level.

Outputs

Related topics:

Analog terminals

( 112)

Electrical data

( 120)

Identifier

Data type

Value/meaning

nIn1_a

C033/1

| INT

Analog input 1

• Scaling:

±2

14

≡ ±10 V for use as voltage input

+2

14

≡ +20 mA for use as current input

bCurrentErrorIn1

BOOL

Status signal "Current input error"

• Only when analog input 1 is used as current input.

• Application: Cable-breakage monitoring of the 4 ...20 mA circuit.

TRUE |I

AIN1

| < 4 mA

/6B$QDORJ,QSXW

$,QBE&XUUHQW(UURU,Q

$,QB2XW

&
&







'

$

&

2IIVHW

*DLQ

&

&

&

&

&

(UURUUHDFWLRQ

$8

0LQLPXPDQDORJVHWSRLQW

Advertising