4 cause & possible remedies, Cause & possible remedies, Oc5: ixt overload – Lenze 8400 BaseLine D User Manual

Page 157: Su02: mains voltage switched-off, Xx.0119.00050, Xx.0119.00001, Xx.0111.00002, 8diagnostics & error management

Advertising
background image

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

157

8

Diagnostics & error management

8.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.7.4

Cause & possible remedies

This chapter contains all error messages of the controller operating system in numerical order of the

error numbers. The list provides detailed information on the response to the error message as well

as information on the cause & possible remedies.

Tip!
A list of all error messages of the controller operating system in alphabetical order can be

found in the previous chapter "

Short overview (A-Z)

"

( 156)

.

Su02: One mains phase is missing [xx.0111.00002]

OH: Heatsink overtemperature [xx.0119.00001]

OC5: Ixt overload [xx.0119.00050]

Note!

For the sake of legibility, the

Logbook

and

C165

display the error number with the follo-

wing syntax:

[Error type].[Error subject area no.].[.].[Error ID]
In this documentation, "xx", a wildcard, stands for the error type since it is configurable

for many error messages.

Response (Lenze setting printed in bold)

Setting:

C565

( Adjustable response)

None  Fault  Trouble  WarningLocked

Cause

Remedy

One mains phase of a three-phase supply has failed.

Check mains connection (terminal X100).

Response (Lenze setting printed in bold)

None  Fault  Trouble  WarningLocked

Cause

Remedy

The heatsink temperature is higher than the fixed limit

temperature (90 ° C).

Maybe the ambient temperature of the controller is too

high or the fan or its ventilation slots are dirty.

• Check control cabinet temperature.

• Clean filter.

• Clean controller.

• If required, clean or replace the fan.

• Provide for sufficient cooling of the device.

Response (Lenze setting printed in bold)

Setting:

C604

( Adjustable response)

None  Fault  Trouble  WarningLocked

Cause

Remedy

The Ixt overload check has tripped.

• Operating threshold = 100 % Ixt (adjustable in

C123

)

Possible causes:

• Wrong dimensioning of the device with regard to its

motor load.

• Load cycles are not complied with.

• Check and, if required, correct dimensioning of the

device and the motor load with regard to technical

data.

• Reduce motor load cycles (observe load cycles accor-

ding to documentation).

Advertising