2 drive diagnostics with the »engineer, Drive diagnostics with the »engineer, 8diagnostics & error management – Lenze 8400 BaseLine D User Manual

Page 143

Advertising
background image

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

143

8

Diagnostics & error management

8.2

Drive diagnostics with the »Engineer«

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.2

Drive diagnostics with the »Engineer«

When an online connection to the controller has been established, the connected controller can be

diagnosed and relevant actual controller states can be displayed in a clearly arranged visualisation

using the »Engineer« :

Information on the drive diagnostics with the integrated keypad can be found in the

chapter "Introduction" in the subchapter "

Internal Keypad

":

LED status display

( 19)

Display messages

( 20)

Button

Function

Display all active sources of a controller inhibit.

Display all active sources of a quick stop.

Resetting an error

Acknowledge fault message (if the error cause has been eliminated).

Logbook...

Display the Logbook

of the controller.

( 146)

Monitoring...

Configure the Monitoring

.

( 148)

Device state...

Display the internal state machine including the current device state.

Drive control...

Display the bit assignment of the following control-related words:

• Cause of controller inhibit (

C158

)

• Cause of quick stop QSP (

C159

)

• Status word (

C150

)

• Extended status word (

C155

)

Device information...

Display identification data, e.g. information on firmware version.

Advertising