5motor control (mctrl) – Lenze 8400 BaseLine D User Manual

Page 67

Advertising
background image

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

67

5

Motor control (MCTRL)

5.1

Motor selection/Motor data

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Motor data
In the parameterisation dialog, the data of the motor nameplate for the selected motor are display-

ed under "Motor data".

Actual values
When an online connection to the controller has been established, the following actual values are

displayed in the parameterisation dialog under "Actual values":

Note!

Sensorless vector control in particular requires the motor data parameters to be set. The

motor data comprise the data of the motor nameplate and the data of the motor equi-

valent circuit.
If the motor has been selected via the motor catalogue of the »Engineer« or the motor

data have been adapted offline using the »Engineer«, all motor data must then be co-

pied to the controller and saved power-failure-proof to the memory module (device

command:

C002/11

) when an online connection has been established.

Parameter

Info

C081

Rated motor power

C087

Rated motor speed

C088

Rated motor current

C089

Rated motor frequency

C090

Rated motor voltage

C091

Motor cos ϕ

Parameter

Info

C051

Actual speed value

C052

Motor voltage

C053

DC-bus voltage

C054

Motor current

C066

Thermal motor load (I2xt)

Highlighted in grey = display parameter

Advertising