C00073 | vp imax controller, C00074 | ti imax controller, C00081 | rated motor power – Lenze 8400 BaseLine D User Manual

Page 183: C00084 | motor stator resistance, C00085 | motor stator leakage inductance, C081, C084, C085, Akage inductance, C074/1

Advertising
background image

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

183

9

Parameter reference

9.2

Parameter list | C00073

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00073

C00074

C00081

C00084

C00085

Parameter | Name:

C00073 | Vp Imax controller

Data type: UNSIGNED_16

Index: 24502

d

= 5FB6

h

Amplification factor Vp for Imax controller
Setting range

(min. value | unit | max. value)

Lenze setting

0.00

16.00 0.25

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00074 | Ti Imax controller

Data type: UNSIGNED_16

Index: 24501

d

= 5FB5

h

Reset time Ti for Imax controller
Setting range

(min. value | unit | max. value)

Lenze setting

12

ms

9990 65 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00081 | Rated motor power

Data type: UNSIGNED_16

Index: 24494

d

= 5FAE

h

This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor

catalogue, the suitable value can be entered automatically.

Note:

It is mandatory to give the rated motor power for the sensorless vector control (

SLVC

).

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

kW

99.00 11.00 kW

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00084 | Motor stator resistance

Data type: UNSIGNED_32

Index: 24491

d

= 5FAB

h

After the motor to be used has been selected from the motor catalogue, the suitable value can be entered automati-

cally. An automatic detection via the motor parameter identification is possible as well.
Setting range

(min. value | unit | max. value)

Lenze setting

0

mohm

200000 330 mohm

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00085 | Motor stator leakage inductance

Data type: UNSIGNED_16

Index: 24490

d

= 5FAA

h

After the motor to be used has been selected from the motor catalogue, the suitable value can be entered automati-

cally. An automatic detection via the motor parameter identification is possible as well.
Setting range

(min. value | unit | max. value)

Lenze setting

0.00

mH

650.00 0.00 mH

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Advertising