Parameter reference

9.2

Parameter list | C00003

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00003

C00006

Parameter | Name:

C00003 | Status of last device command

Data type: UNSIGNED_8

Index: 24572

d

= 5FFC

h

Status of the device command carried out last (

C00002

).

Note:

Before switching off the supply voltage after carrying out a device command, check whether the device command

has been carried out successfully via the status display!

Drive control (DCTRL)

:

Device commands

Selection list

(read only)

Info

0 Successful

Device command has been carried out successfully.

1 Command unknown

Device command is implausible or not known in the sys-

tem.

2 No access

Access for requested device command is not approved.

3 Time-out

Device command could not be processed in the defined

time (time-out).

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00006 | Motor control

Data type: UNSIGNED_8

Index: 24569

d

= 5FF9

h

Selection of the motor control mode

Motor control (MCTRL)

:

Select control mode

Selection list

(Lenze setting printed in bold)

Info

4 SLVC: Vector control

This control type is used for sensorless vector control of

an asynchronous motor.

• The control type requires motor parameters to be set

as exactly as possible!

Sensorless vector control

6 VFCplus: V/f linear

This control type is used for the speed control of an asyn-

chronous motor via a linear V/f characteristic and is the

simplest control type.

• For setting the V/f characteristic, only the rated fre-

quency (

C00089

) and the rated voltage (

C00090

) of

the motor have to be entered.

V/f characteristic control

8 VFCplus: V/f quadr

This control type is used for speed control of an asynchro-

nous motor via a square-law V/f characteristic.

• For setting the V/f characteristic, only the rated fre-

quency (

C00089

) and the rated voltage (

C00090

) of

the motor have to be entered.

V/f characteristic control

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1