6

I/O terminals

6.2

Analog terminals

114

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Minimum and maximum output speed
The speed range required for the application results from the selected reference speed (

C011

) and

the minimum analog setpoint (

C010

):

• The reference speed set in

C011

is reached at a speed setpoint selection of 100 %.

• All speed setpoint selections are provided in % and always refer to the reference speed set in

C011

(independent of the setpoint source).

• The speed set in

C010

corresponds to the minimum speed if the speed setpoint has been selec-

ted via the analog input (Lenze setting) and a voltage of 0 V is applied to the X4/A1U input ter-

minal.

[6-1]

Relation between the selected setpoint and minimum and maximum output speed

0 V

n

10 V

100 % = C00011

C00010