9 ls_disfree_a, Ls_disfree_a, 10 function library – Lenze 8400 BaseLine D User Manual
Page 244
10
Function library
10.9
LS_DisFree_a
244
Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
10.9
LS_DisFree_a
This system block displays any four analog signals of the application on display codes. The signals
to be displayed are selected via the given configuration parameters.
Inputs
Parameter
Identifier
Data type
Information/possible settings
nDis1_a ... nDis4_a
INT
Inputs for any analog signal of the application
Parameter
Possible settings
Info
-199.9 %
199.9 % Display of the analog signals which
are applied at the nDis1_a ... nDis4_a
inputs.
selection list - analog signals
Configuration parameters for the in-
puts nDis1_a ... nDis4_a
Q'LVBD
Q'LVBD
Q'LVBD
Q'LVBD
&
&
&
&
/6B'LV)UHHBD
&
&
&RQILJXUDWLRQSDUDPHWHUV
&
&