4 electrical data, Electrical data, 6i/o terminals – Lenze 8400 BaseLine D User Manual

Page 120: X101

Advertising
background image

6

I/O terminals

6.4

Electrical data

120

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.4

Electrical data

Terminal

Application / electrical data

GND

Reference potential

A1U

Voltage or current input
General data:

Resolution: 10 bits

(Error: 1 digit ≡ 0.1 %, in relation to the final value)

Conversion rate: 1 kHz

In order to filter short-time faults in the analog signal charac-

teristic, the analog input value is led via a digital lag filter

with a time constant of 5 ms.

Processing cycle: 1 kHz (1 ms)

Electric strength of external voltage: ±15 V, permanent

If used as voltage input:

Level/scaling: When

C034/1

= "0":

0 ... +10 V ≡ 0 ... +2

14

≡ 0 ... +16384 ≡ 0 ... +100 %

When

C034/1

= "1" or "2":

0 ... +5 V ≡ 0 ... +2

14

≡ 0 ... +16384 ≡ 0 ... +100 %

Input resistance: > 50 kΩ

Input voltage in case of open circuit: Display "0" (V< 0.2 V, absolute)

Accuracy: ±0.1 V

If used as current input (with external 250-Ω load resistor; see illustration):

Level/scaling: 0 ... +20 mA ≡ 0 ... +2

14

≡ 0 ... +16384 ≡ 0 ... +100 %

Input resistance: 250 Ω (external)

AR

10-V reference voltage for analog input

maximum output current: 10 mA

12I

12 V voltage for connecting the digital inputs via potential-free contacts

• Internal supply: DC

maximum output current: 50 mA

Electric strength of external voltage: +30 V

Overcurrent protection: Automatic reset

RFR

Controller enable

• Electrical data as in digital inputs

X4

GND

A1U

AR

12I

RFR

DI1

DI2

DI3

DI4

24E

DO1

R = 250

B

W

X101

NO

COM

Advertising