Troubleshooting the Kinetix 2000 Drive System

147

DriveHardFault

(Task init)

E67

Operating system failed.

SHUTDOWN

N

DriveHardFault

(SCANport Comm)

E68

DPI communication failed.

STOP

N

DriveHardFault

(Objects Init)

E69

Non-volatile memory attribute out of range.

SHUTDOWN

N

DriveHardFault

(NV Mem Init)

E70

Non-volatile memory corrupted.

SHUTDOWN

N

DriveHardFault

(Memory Init)

E71

RAM or flash memory validation failure.

SHUTDOWN

N

DriveOvertempFault

(Drive Overtemp)

E72

Inverter temperature limit exceeded.
Firmware I

2

t protection does not generate a fault, rather it

dynamically folds back current when 110% of drive rating is reached.

SHUTDOWN

Y

Communicate

(Backplane Comm)

E73

Power rail backplane CAN communications failed.

STOP

N

DriveOvercurrentFault

(Bus OverCurrent)

E74

The converter has exceeded its converter rating.

SHUTDOWN

N

DriveOvervoltageFault

(Shunt Time Out)

E75

The IAM, AM, or SM has exceeded its shunt resistor continuous
rating. SHUTDOWN for IAM, DISABLE for AM. IAM also provides
fault handling for shunt module.

SHUTDOWN

N

DriveHardFault

(Can Init)

E76

Either DPI or backplane CAN initialization failure.

SHUTDOWN

N

DriveHardFault

(Module Mismatch)

E77

Generated by IAM if the power rating of an AM on the same power
rail does not match with IAM input power rating.

SHUTDOWN

N

DriveHardFault

SERCOS Init

E78

Control hardware fault detected.

SHUTDOWN

N

DriveOvervoltageFault

(Shunt Module Flt)

E79

Power rail mounted shunt module fault. Displayed on IAM
seven-segment Fault Status LED indicator.

SHUTDOWN

N

HardwareFault

(CPLD Flt)

E80

Control hardware fault detected.

SHUTDOWN

N

HardwareFault

(Common Bus Flt)

E81

Common bus follower IAM detected ac input power being applied.

SHUTDOWN

N

HardwareFault

(Pre-charge Timeout Flt)

E90

Pre-charge resistor power exceeds the resistor rating.

SHUTDOWN

N

RESERVED

All
Others

Fault Message RSLogix
(HIM)

Error
Code

Description

Drive Fault
Action

RSLogix
Programmable
Fault Action?