Publication 2093-UM001A-EN-P — January 2007

Connecting the Kinetix 2000 Drive System

97

Wiring 15-pin Panel-mounted Breakout Kit

A panel-mounted breakout kit, catalog number 2090-UXBK-D15xx, is
available. This kit permits connection between a motor feedback device and
the motor feedback (MF) connector. A cable connects between a
panel-mounted terminal block and the 15-pin motor feedback (MF)
connector. Wires from an external motor feedback device interface via the
panel-mounted terminal block.

15-pin and 44-pin Breakout Kits for Use with Kinetix2000 Drives

Wiring 44-pin Panel-mounted Breakout Kit

A panel-mounted breakout kit, catalog number 2090-U3BK-D44, is available.
This kit permits connection between external devices and the input/output
and auxiliary feedback (IOD/AF) connector. A cable connects between a
panel-mounted terminal block and the 44-pin I/O and auxiliary feedback (IO/
AF) connector. Wires from external devices interface via the panel-mounted
terminal block.

Kinetix2000 Drive

(2093-AC05-MP

x

is shown)

2090-U3BC-D44

xx

Breakout Cable

44 pin

I/O and Auxiliary

Feedback

Connector

2090-U3BB-D44
Panel-mounted
Terminal Block

Wire Terminations

15 pin

Motor

Feedback

Connector

2090-UXBB-D15
Panel-mounted
Terminal Block

Wire

Terminations

2090-UXBC-D15

xx

Breakout Cable

IMPORTANT

The 15-pin and 44-pin breakout blocks accept wire in the range of
4…0.14 mm

2

(12…26 AWG).