Power dissipation specifications – Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual

Page 160

Advertising
background image

Publication 2093-UM001A-EN-P — March 2007

160

Specifications and Dimensions

Power Dissipation
Specifications

Use the following table to size an enclosure and calculate required ventilation
for your Kinetix 2000 system.

Kinetix 2000 Modules

Usage as a Percentage of Rated Power Output (Watts)

20%

40%

60%

80%

100%

Converter (IAM)

(1)

2093-AC05-MP1

Three-phase

7.0 10.5 14.0 17.4 20.9

2093-AC05-MP2

2093-AC09-MP5

2093-AC05-MP1

Single-phase

5.8 8.0 10.3 12.6 14.8

2093-AC05-MP2

2093-AC09-MP5

Inverter (IAM and AM)

(1)

2093-AC05-MP1

and

2093-AMP1

31.6 33.6 35.6 37.6 39.6

2093-AC05-MP2

and

2093-AMP2

33.0 36.4 39.8 43.3 46.8

2093-AC05-MP5

and

2093-AMP5

36.2 42.9 49.8 56.8 63.9

2093-AM01

38. 3

46.7

55. 3

64. 1

73. 1

2093-AM02 44.

3

55.6

67.

3

79.2

91.4

Shunt module (SM)

2093-ASP06

35.8 45.8 55.8 65.8 75.8

Power Rail

2093-PRSxx

0 0 0 0 0

Connector Kit

2093-K2CK-D15M

0 0 0 0 0

(1)

Internal shunt power is not included in the calculations and must be added based on utilization.