Wiring the motor brake (bc) connector, Wiring the motor brake (bc) connector o, 89 fo – Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual

Page 89: Wiring 24v dc brake input power connections, Important

Advertising
background image

Publication 2093-UM001A-EN-P — January 2007

Connecting the Kinetix 2000 Drive System

89

connects to the closest earth ground. The termination wire may be extended
to the full length of the motor pigtail if necessary, but it is best to connect the
supplied wire directly to ground without lengthening.

Pigtail Terminations

(1)

Remove paint from machine frame to ensure proper HF-bond between machine frame and motor case, shield
clamp, and ground stud.

Wiring the Motor Brake (BC) Connector

This example applies to axis modules (AM) and the inverter section of
integrated axis modules (IAM).

Integrated Axis Module/Axis Module (BC connector)

Wiring 24V dc Brake Input Power Connections

(1)

(1)

Pigtail Cable

TL-Series or

Y-Series

Motor

Connectors

Motor Power Cable

Machine Frame

150 mm (6.0) Termination

Cable Braid Clamped

to Machine Frame.

(1)

IMPORTANT

If your system includes a line interface module (LIM), you can source
the 24V dc from the LIM (P1L or PSL connector).

4 3 2 1

PWR

MBRK+

MBRK-

COM

Integrated Axis Module

(2093-AC05-MPx shown)

Advertising