Specifications and Dimensions

Auxiliary Control Power Specifications

This section lists auxiliary control power requirements for a Kinetix 2000
system comprised of an IAM, up to seven AMs, a Shunt Module, or a Slot
Filler.

Auxiliary Control Power Specifications

Number of AMs
(2093-AMPx or
2093-AMx)

Current Requirements
(115V ac)

Current Requirements
(230V ac)

Max Inrush

Input VA

0

0.3 A

0.15 A

93 A

50 VA

1

0.6 A

0.30 A

99 VA

2

0.9 A

0.45 A

148 VA

3

1.2 A

0.60 A

197 VA

4

1.5 A

0.75 A

247 VA

5

1.8 A

0.90 A

296 VA

6

2.1 A

1.05 A

345 VA

7

2.4 A

1.20 A

395 VA

Shunt Module

(2093-ASP06)

2.5 A

1.25 A

410 VA

Slot Filler
(2093-PRF)

— — — —