Removing and Replacing the Kinetix 2000 Drive Modules

Replace the Power Rail

This procedure assumes you do not need to change the location of the power
rail on the panel, because you intend to reuse the mounting bolts in their
existing locations to mount a new power rail.

Follow these steps to replace the power rail.

1. Align the replacement power rail over the existing mounting bolts.

2. Tighten the mounting bolts.

3. Re-attach the braided grounding strap to the power rail grounding stud

(refer to page 151).

IMPORTANT

If you need to change the location of the power rail, or if you are
installing a power rail designed for additional or fewer modules than
you removed, refer to Kinetix 2000 Power Rail Installation
Instructions, publication 2093-IN004.

ATTENTION

To avoid damage to the power rail during installation, do not remove
the protective boots until the module for each slot is ready for
mounting.

IMPORTANT

To improve the bond between the power rail and subpanel,
construct your subpanel out of zinc plated (paint-free) steel.