IAI America ASEL User Manual

Page 109

Advertising
background image

Part 2 Programs

Chapter 2 List of SEL

Language Command Codes

87

Part 2 Programs

Operation type in the output field

CC: Command was executed successfully, ZR: Operation result is zero,

PE: Operation is complete, CP: Command part has passed, TU: Time up

EQ: Operand 1 = Operand 2, NE: Operand 1 z Operand 2,

GT: Operand 1 > Operand 2, GE: Operand 1 t Operand 2,

LT: Operand 1 < Operand 2, LE: Operand 1 d Operand 2

Category Condition Command

Operand 1

Operand 2

Output

Function

Page

Optional

SV††

Operation axis pattern

Prohibited

PE

Servo [ON, OF]

161

Optional

HOME

Home-return axis pattern

Prohibited

PE

Return to home

162

Optional

MOVP

Destination position number Prohibited

PE

Move to specified position

163

Optional

MOVL

Destination position number Prohibited

PE

Move to specified position via

interpolation

164

Optional

MVPI

Travel position number

Prohibited

PE

Move to relative position

165

Optional

MVLI

Travel position number

Prohibited

PE

Move to relative position via

interpolation

166

Optional

MOVD

Target position

(Axis pattern)

PE

Move via direct value specification

167

Optional

MVDI

Travel distance

(Axis pattern)

PE

Move relatively via direct value

specification

168

Optional

PATH

Start position number

End position number

PE

Move along path

169

Optional

J†W† Axis operation pattern

Start I/O, flag

PE

Jog [FN, FF, BN, BF]

170

Optional

STOP

Axis stop pattern

Prohibited

CP Decelerate and stop axis

171

Optional

PSPL

Start position number

End position number

PE

Move along spline

172

Optional

PUSH

Target position number

Prohibited

PE

Move by push motion

173

Optional

PTRQ

Axis pattern

Ratio [%]

CC

Change push torque limit

parameter

175

Optional

CIR2

Passing position 1 number

Passing position 2

number

PE

Move along circle 2 (arc

interpolation)

176

Optional

ARC2

Passing position number

End position number

PE

Move along arc 2 (arc

interpolation)

177

Optional

CHVL

Axis pattern

Speed

CP Change speed

178

Optional

ARCD

End position number

Center angle [deg]

PE

Move along arc via specification of

end position and center angle

179

Optional

ARCC

Center position number

Center angle [deg]

PE

Move along arc via specification of

center position and center angle

180

Optional

PBND

Axis pattern

Distance

CP Set positioning band

181

Optional

CIR

Passing position 1 number

Passing position 2

number

PE

Move along circle (CIR2 is

recommended)

182

Optional

ARC

Passing position number

End position number

PE

Move along arc (ARC2 is

recommended)

183

Refer to the page on palletizing for commands relating to arch motion.

Optional

ARCH

Position number

Position number

PE

Arch motion

216

Optional

ACHZ

Axis number

Prohibited

CP Declare arch-motion Z-axis

218

Optional

ATRG

Position number

Position number

CP Set arch trigger

219

Actuator

control

command

Optional

OFAZ

Offset value

Prohibited

CP Set arch-motion Z-axis offset

220

Optional

IF††

Comparison variable

Comparison value

CP Compare [EQ, NE, GT, GE, LT,

LE]

184

Optional

IS††

Column number

Column number,

character literal

CP Compare strings

185

Prohibited

ELSE

Prohibited

Prohibited

CP

Declare execution destination

when IF command condition is not

satisfied

186

Structural

IF

Prohibited

EDIF

Prohibited

Prohibited

CP Declare end of IF

186

Optional

DW†† Comparison variable

Comparison value

CP Loop [EQ, NE, GT, GE, LT, LE]

187

Optional

LEAV

Prohibited

Prohibited

CP Pull out from DO

187

Optional

ITER

Prohibited

Prohibited

CP Repeat DO

188

Structural

DO

Prohibited

EDDO

Prohibited

Prohibited

CP Declare end of DO

188

Optional

SLCT

Prohibited

Prohibited

CP Declare start of multi-branching

189

Prohibited

WH†† Comparison variable

Comparison value

CP Branch value [EQ, NE, GT, GE,

LT, LE]

190

Prohibited

WS†† Column number

Column number,

character literal

CP Branch character string [EQ, NE]

191

Prohibited

OTHE

Prohibited

Prohibited

CP Declare branching destination

when condition is not satisfied

192

Multi-

branching

Prohibited

EDSL

Prohibited

Prohibited

CP Declare end of SLCT

192

Advertising