Part 2 Programs

Chapter 3 Explanation of Commands

156

Part 2 Programs

z

VLMX (Specify VLMX speed)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,

declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional

Optional

VLMX

Prohibited Prohibited

CP

[Function] Set the actuator travel speed to the VLMX speed (normally maximum speed).

Executing a VLMX command will set the value registered in “Axis-specific parameter No. 29,

VLMX speed” as the travel speed.

(Note)

If the VLMX speed is specified in a continuous position travel command (PATH, PSPL), the

target speed to each position will become a composite VLMX speed not exceeding the

maximum speed of each axis set in “Axis-specific parameter No. 28, Maximum operating

speed of each axis.” To make the target speed constant, a desired speed must be expressly

specified using a VEL command.

[Example]

VEL

1000

MOVP

1

The speed becomes 1000 mm/sec in this section.

MOVP

2

VLMX

MOVP

3

The speed becomes VLMX mm/sec in this section.

MOVP

4