IAI America ASEL User Manual

Page 409

Advertising
background image

Appendix

List of Parameters

387

Appendix

Axis-Specific Parameters

No

Parameter name

Default value

(Reference) Input range

Unit

Remarks

57 Push-abort deviation ratio at

positioning

5000

1 ~ 99999

Deviation is compared against “Steady-state deviation of

push speed + Push-speed pulse speed x Abort deviation

ratio.”

58 Positioning band

100

1 ~ 9999

0.001 mm

59 Allowable deviation error

ratio

(Maximum speed pulse

ratio)

27

1 ~ 9999

Deviation is compared against “Steady-state deviation of

maximum operating speed of each axis + Pulse speed of

maximum operating speed of each axis x Allowable deviation

error ratio.”

60 Position gain

30

1 ~ 9999

/s

61 FAG

0

0 ~ 999

62 Synchro FB gain

77

0 ~ 1000

63 Stop special output range

1

0 ~ 9999

Pulse

Invalid if “0” is set.

64 Stop special output value

1

0 ~ 999

DRVVR

65 Mating synchro-axis number

0

0 ~ 8

Must be input for both axes. (Of the axis pair, the axis with

the smaller axis number becomes the master axis. Both axes

must have the same resolution characteristics. Commands

cannot be issued to the slave axis.) (Invalid if “0” is set)

66 Mode selection for rotational

movement axis

0

0 ~ 5

0: Normal, 1: Index mode

67 Short-cut control selection

for rotational movement axis

0

0 ~ 5

0: Do not select, 1: Select (Valid only in the index mode

AND when an incremental encoder is used)

68 Mode selection for linear

movement axis

0

0 ~ 5

0: Normal, 1: Infinite-stroke mode (Note: Positioning

boundary applies. This setting can be specified only when

an incremental encoder is used.)

69 (For expansion)

0

~

70 For future expansion

0

Reference

only

71 For future expansion

0

Reference

only

72 DRVVR + offset

0

Reference

only

DRVVR

(Change prohibited) To maintain symmetry of the positive

and negative sides.

73 DRVVR – offset

0

Reference

only

DRVVR

(Change prohibited) To maintain symmetry of the positive

and negative sides.

74 For future expansion

0

Reference

only

75 For future expansion

0

Reference

only

76 Home-adjustment

parameter set selection

1

Reference

only

(Change prohibited)

0: P21 = Phase-Z evacuation distance at INC home return

P12 = Ideal phase-Z position coordinate

1: P32 is read automatically even when P33 = 0. P33 = 0

indicates “actual distance.”

P21 = Offset travel at home return

P12 = Coordinate achieved by offset travel at home return

P26 = Invalid

(To facilitate adjustment)

77 Synchro S pulse

3

0 ~ 99999

Pulse

78 Maximum takeoff command

amount

0

-3000 ~

3000

0.001 mm Maximum lift command amount before brake unlock (Input

with sign)

(Suppression of momentary drop upon servo ON when a

heavy object is placed)

* Important: Input using the same sign as the rising

coordinate direction. (0.100 mm to 0.500 mm in absolute

value as a guideline)

* The servo-ON check time (axis-specific parameter No. 30)

must also be extended (approx. 1000 to 1500 msec) to

provide a sufficient time for rise-direction torque to follow.

(Valid only when installation of brake is specified.)

79 Actual takeoff check

distance

5

0 ~ 3000

0.001 mm Absolute value input

80 Maximum forced-feed range

0

0 ~ 9999

0.001 mm For reduction of settling time. (Invalid range if “0” is set)

(Approx. 1.000 mm as a guideline)

81 Minimum forced-feed range

200

0 ~ 9999

0.001 mm

82 Medium forced-feed range

600

0 ~ 9999

0.001 mm

83 Absolute synchro slave-axis

initialization cancellation

0

0 ~ 5

Valid only with a synchro slave axis.

Advertising