IAI America ASEL User Manual

Page 193

Advertising
background image

Part 2 Programs

Chapter 3 Explanation of Commands

171

Part 2 Programs

z

STOP (Stop movement)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,

declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional

Optional

STOP

Axis

pattern

Prohibited

CP

[Function] Decelerate and stop the axes specified by the axis pattern in operand 1.

(Note 1)

A STOP command can be used with all active servo commands other than a SVOF

command.

(Note 2)

A STOP command only issues a deceleration-stop command (operation stop) to a specified

axis pattern and does not wait for stopping to complete. Issuing other servo commands to a

decelerating axis will either become invalid or generate an “axis duplication error,” etc.

Set a timer, etc., in the program so that the next servo command will be issued after a

sufficient deceleration-stop processing time elapses.

Even when a STOP command is to be issued to an axis currently stopped, provide a

minimum interval of 0.1 second before the next servo command is issued.

[Example 1]

STOP

11

Decelerate and stop axes 1 and 2.

[Example 2]

The axis pattern can be specified indirectly using a variable.

When the command in [Example 1] is rephrased based on indirect specification using

a variable:

11 (binary) o 3 (decimal)

LET

1

3

Assign 3 to variable 1.

STOP

*1

Advertising