IAI America ASEL User Manual

Page 338

Advertising
background image

Part 3 Positioner Mode

Chapter 3 Product Switching Mode

316

Part 3 Positioner Mode

5.3

Movements through Positions

Timings of how the actuator moves through positions are illustrated below.

Timing Chart of Movement through Positions (Standard Positioner Mode)

Ti: At least 6 msec

Operate the actuator to move through positions by following the procedure explained below.

* Confirm beforehand that the positioning complete output signal, home-return complete output signal and

servo-ON status output signal are all ON.

[1] Change the previous product/position number inputs to different product/position numbers.

[2] Turn ON the start input signal.

[3] Confirm that the positioning complete output signal is OFF.

[4] Turn OFF the start input signal.

[5] Confirm that the positioning complete output signal is ON.

Repeat steps [1] through [5] sequentially.

* Pause and *cancellation inputs are contact-B input signals (always ON), so keep these signals ON while

the actuator are moving through the specified positions.

Input

Output

Start

Servo ON

Product/

position input

Alarm

Ready

Positioning complete

Home return complete

Servo ON status

Advertising