Part 2 Programs

Chapter 3 Explanation of Commands

161

Warning : Turning the servo ON near the mechanical end may disturb the magnetic pole phase

detection, and may cause the magnetic pole unconfirmed error or the magnetic pole

detection error.

Put the slider or rod away from the mechanical end when turning the servo ON.

Part 2 Programs

1.12

Actuator Control Command

SV

(Turn ON/OFF servo)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,

declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional

Optional

SV

Axis

pattern

Prohibited

PE

[Function]

Turn ON/OFF the servos of the axes specified by the axis pattern in operand 1.

SV

ON

Turn ON the servo.

OF

Turn OFF the servo.

[Example 1]

SVON

11

Turn ON the servos of axes 1 and 2. Nothing will occur if the

axis servos are already ON.

[Example 2]

The axis pattern can be specified indirectly using a variable.

When the command in [Example 1] is rephrased based on indirect specification using

a variable:

11 (binary)

3 (decimal)

LET

1

3

Assign 3 to variable 1.

SVON

*1