IAI America ASEL User Manual

Page 372

Advertising
background image

Appendix

Battery Backup Function

350

Appendix

The absolute encoder backup specifications are shown in the table below.

List of Absolute Encoder Backup Functions

Battery type

AB-5 (by IAI)

Battery voltage

3.6 V

Current capacity

2000 mAH

Detection voltage for battery

voltage low alarm

(Typical) 3.1 V 3.0 V a 3.2 V

Detection voltage for battery

voltage low error

(Typical) 2.5 V 2.3 V ~ 2.7 V

Time after alarm detection until

error detection (reference)

10 days at 20qC based on continuous operation; 7 days if the power is not

supplied.

10 days at 40qC based on continuous operation; 2.5 days if the power is not

supplied.

Minimum data retention voltage Min. 2.7 V

(Varies depending on the encoder characteristics.)

Time after error detection until

data loss (reference)

With an absolute encoder, an absolute reset must be performed once an

error is detected.

Data protection time during

battery replacement

15 minutes (Maximum retention time when

no battery is installed in the battery holder)

Data is retained by the super

capacitor inside the controller.

Temperature 40qC, power supplied 0% of

the time

2 years

Guide on when to replace

battery

Temperature 40qC, power supplied 50%

of the time

4 years

Advertising