Part 3 Positioner Mode

Chapter 4 2-axis Independent Mode

325

Part 3 Positioner Mode

5.2

Home Return

Timings associated with home-return operation are illustrated below. The figures in parentheses indicate

port numbers for axis 2.

Timing Chart of Home-return Operation (Standard Positioner Mode)

Perform home-return operation by following the procedure explained below.

* Before commencing the procedure, confirm that the ready output signal and alarm output signal are OFF.

[1] Turn ON the servo ON input signal.

[2] Confirm that the servo-ON status output signal is ON.

[3] Turn ON the home-return input signal.

[4] Confirm that the positioning complete output signal is OFF.

[5] Turn OFF the home-return input signal.

[6] Confirm that the home-return complete output signal is ON. Home return is now completed.

*Pause and *cancellation inputs are contact-B input signals (always ON), so keep these signals ON while home return

is in progress.

To initiate home return using the home-return signal input, the servo ON input signal must be ON. These operation

commands will not be accepted if the servo ON input signal is OFF. Note, however, that only the commands will be

ignored and no error will generate.

Input

Output

Start

Home return

Servo ON

Alarm

Ready

Positioning complete

Home return complete

Servo ON status

Home return in progress

Warning : Turning the servo ON near the mechanical end may disturb the magnetic pole phase

detection, and may cause the magnetic pole unconfirmed error or the magnetic pole

detection error.

Put the slider or rod away from the mechanical end when turning the servo ON.