IAI America ASEL User Manual

Page 171

Advertising
background image

Part 2 Programs

Chapter 3 Explanation of Commands

149

Part 2 Programs

z

SCRV (Set sigmoid motion ratio)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,

declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional

Optional

SCRV

Ratio

Prohibited

CP

[Function] Set the ratio of sigmoid motion control of the actuator in the value specified in operand 1.

The ratio is set as an integer in a range from 0 to 50 (%).

a

b

X 100 (%)

If the ratio is not set using this command or 0% is set, a trapezoid motion will be

implemented.

A SCRV command can be used with the following commands:

MOVP, MOVL, MVP

{

, MVL

{

, JBWF, JBWN, JFWF, JFWN

MOVD, MODI

[Example 1]

SCRV

30

Set the sigmoid motion ratio to 30%.

a

b

Speed

Time