Part 1 Installation

Chapter 4 Operation

57

Part 1 Installation

Note) The assignments of dedicated

input/output port functions (such

as RDY output start signal)

reflect the factory settings.

Controller

Power ON

READY signal ON

Program number

confirmed?

N

N

N

N

Y

Y

Y

N

N

Y

N

Y

Start signal

confirmed?

Program run

Emergency-stop

signal confirmed?

Controller

error?

Servo OFF

ALARM signal ON

Alarm output

Emergency-stop

input

External start input

Program number

input

Ready output

External device

Power ON

READY signal

confirmed?

Various I/O

processing

Program number

specification

Start signal ON

Emergency-stop

switch ON?

Emergency-stop

signal ON

ALARM signal

confirmed?

ALARM

processing

Y

Y

3.2

Starting via External Signal Selection

(1) Flow chart

When the READY signal (Output

port No. 301) turns ON, the RDY

lamp (green) on the controller front

panel will illuminate.

Input a desired program number as

a BCD code from the external

device (Input port Nos. 16 through

22).

Input a start signal (input port No. 0)

from the external device.

If the optional panel unit is

connected, the CODE display area

indicates the program number of

each program that has been

started.

If an emergency-stop signal was

input from the external device or a

controller error occurred, the

controller will turn off the servo

power. (The RDY lamp will turn

off.)

Select a desired program number externally and then input a start signal.