Part 2 Programs

Chapter 3 Explanation of Commands

163

Part 2 Programs

z

MOVP (Move PTP by specifying position data)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,

declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional

Optional

MOVP

Position

number

Prohibited

PE

[Function] Move the actuator to the position corresponding to the position number specified in operand

1, without interpolation (PTP stands for “Point-to-Point”).

The output will turn OFF at the start of axis movement, and turn ON when the movement is

complete.

[Example 1]

VEL

100

Set the speed to 100 mm/s.

MOVP 1

Move the axes to the position corresponding to position No.

1 (200, 100).

[Example 2]

VEL

100

Set the speed to 100 mm/s.

LET

1

2

Assign 2 to variable 1.

MOVP *1

Move the axes to the position corresponding to the content

of variable 1 (position No. 2, or (100, 100)).

Position data display in PC software

No.

Axis 1 (X-axis) Axis 2 (Y-axis)

Vel

Acc

Dcl

1

200.000

100.000

2

100.000

100.000

(Note) If no position data is available and acceleration and deceleration are not specified by an ACC

(DCL) command, each axis will move according to all-axis parameter No. 11, “Default

acceleration” and all-axis parameter No. 12, “Default deceleration.”

Travel path from the home to the position corresponding to position No. 1 (200, 100)

X-axis

Y-axis

Only the Y-axis completes

movement.

Each axis moves at 100 mm/s.

Home 0

100 mm

100 mm

200 mm