IAI America ASEL User Manual

Page 386

Advertising
background image

Appendix

Parameter Utilization

364

Appendix

Home return is desired in vertical installation
Driver parameters No.39 “Push torque limit at home return”

No.

Parameter name

Default value

Input range

Unit

39

Push torque limit at home return

120

0 ~ 150

%

Ɣ Explanation of setting

In case home return completes in front of the proper position because of the sliding resistance being

increased in vertical installation due to how to affix the unit or the condition of load, check the value set

in this parameter and adjust it if necessary.

Ɣ Set value

The home return torque gets increased if the value is made bigger.

Setting Reference: Set value = 120% (when direction of home return is upwards) to 80% (when direction

of home return is downwards)