Appendix

List of Parameters

390

Appendix

Driver parameters

No.

Parameter name

Default value

(Reference)

Input range

Unit

Remarks

29

Motor/encoder characteristic word

(compatible with E, priority on E)

(configuration information)

0000H

Reference

only

For adjustment by the manufacturer

30

Motor/encoder control word 1

(compatible with E, priority on E)

(configuration information)

5000

Reference

only

0.1 K (Kelvin =

temperature unit)

For adjustment by the manufacturer

31

Motor/encoder control word 2

(compatible with E, priority on E)

(configuration information)

0000H

Reference

only

For adjustment by the manufacturer

32

Motor/encoder control word 3

(configuration information)

(encoder cable length) [m]

2

1 ~ 30

Encoder cable length (m)

If the encoder has been replaced, don’t

forget to change the setting of this

parameter.

33

Motor/encoder control word 4

(configuration information)

14H

Reference

only

For adjustment by the manufacturer

34

Motor/encoder control word 5

(configuration information)

0000H

Reference

only

For adjustment by the manufacturer

35

(Configuration information)

0000H

Reference

only

For adjustment by the manufacturer

36

(Configuration information)

0000H

Reference

only

For adjustment by the manufacturer

37

(Configuration information)

0000H

Reference

only

For adjustment by the manufacturer

38

Push torque limit at positioning

70

0 ~ 70

%

39

Push torque limit at home return

120

0 ~ 150

%

40

Maximum torque limit

300

10 ~ 400

%

*The maximum value that can be set varies

depending on the motor, etc.

41

Dynamic brake operation

specification

0

0 ~ 1

(Data for other model)

42

Software DB operation

specification

0

0 ~ 1

0: Disable, 1: Enable

43

Speed loop proportional gain

500

1 ~ 32767

Proportional gain

44

Speed loop integral gain

1667

1 ~ 3276700

Integral gain

45

Torque filter time constant

0

0 ~ 2500

46

Current control band number

4

0 ~ 4

47

Current ON time for excited-

phase signal detection step

128

0 ~ 32767

ms

48

Excited-phase signal detection

method

1

0 ~ 2

0: Current suppression method

1: Distance suppression method

2: Distance suppression method (300%

excitation) (Main application version

0.10 or later)

49

Excited-phase signal detection

direction

0

0 ~ 1

0: CW, 1: CCW

50

Excited-phase fixed mode:

Torque-limit switching type

0

0 ~ 1

(Data for other model)

51

Excited-phase fixed mode:

Torque limit

0

0 ~ 100

%

(Data for other model)

52

(For expansion)

0H

0000H ~

FFFFH

53

Current control word 1

0H

Reference

only

54

Current control word 2

0H

Reference

only

The factory setting conforms to the standard

specification of the actuator.

The home return torque becomes higher as

the value gets larger.

This does not usually need a change,

however, it may be necessary to make the

value larger when the home return

operation completes before reaching the

proper position due to increase of slider

resistance depending on the way to mount

or the condition of load in vertical oriented

mounting.

Setting Reference: Set value = 120% (when

direction of home return is upwards) to 80%

(when direction of home return is

downwards)