Other parameters, Appendix list of parameters 394 appendix – IAI America ASEL User Manual

Page 416

Advertising
background image

Appendix

List of Parameters

394

Appendix

7. Other Parameters

No.

Parameter name

Default value

(Reference)

Input range

Unit

Remarks

1 Auto-start program

number

0

0 ~ 64

(Invalid if “0” is set)

2 I/O processing program

number at

operation/program abort

0

0 ~ 64

The start trigger is determined from the “I/O processing

program start type at operation/program abort.” (Note: This

program will be started before confirming an abort of other

programs.)

(Invalid if “0” is set) * If the setting is valid, the number of user

program tasks that can be used will decrease by 1.

3 I/O processing program

number at all operation

pause

0

0 ~ 64

This program will be started when an all-operation-pause

command is issued due to an all-operation-pause factor. (Only

when a program is running) (Invalid if “0” is set) * If the setting

is valid, the number of user program tasks that can be used will

decrease by 1.

4 Program abort type at

error

0

0 ~ 5

0: Cancel only the program in which an error of operation-

cancellation level or higher has generated. (If the error

requires the drive source to be cut off or a servo-OFF or all-

axis servo-OFF request to be issued, all programs other

than the “I/O processing program at operation/program

abort” will be cancelled.)

1: Cancel all programs other than the “I/O processing program

at operation/program abort” when an error of operation-

cancellation level or higher has generated.

5 I/O processing program

start type at

operation/program abort

0

0 ~ 5

0: When all-operation-cancellation factor has generated (Only

when a program is running)

1: When all-operation-cancellation factor has generated

(Always)

2: All-operation-cancellation factor + Error of operation-

cancellation level or higher (“Other parameter No. 4 = 0” is

considered) (Only when a program is running)

3: All-operation-cancellation factor + Error of operation-

cancellation level or higher (“Other parameter No. 4 = 0” is

considered) (Always)

6 PC/TP reconnection delay

at software reset

14000

1 ~ 99999

msec * The setting will become effective after the controller, PC or

TP is restarted.

7 Auto program start setting

1

0 ~ 5

0: Do not start the auto-start program upon power ON

reset/software reset

1: Start the auto-start program

8 (For expansion)

0

9 For future expansion

(change prohibited)

0

0 ~ 2

10 Emergency-stop recovery

type

0

0 ~ 4

0: Abort operations/programs

1: Recovery after reset

2: Operation continued (Only during automatic operation.

* Operation commands from the PC/TP will be aborted on

the PC/TP side.)

3: Abort operations/programs (Software reset when the

emergency stop is reset. The home-return completion

status of incremental-encoder axes will be reset (EG

approximation swap).)

4: Abort operations/programs (Error reset (only with an error

of operation-cancellation level or lower) and auto-start

program start (only if AUTO mode AND other parameter

No. 7 = 1 AND I/O parameter “Input function selection” z 17

AND all-operation-cancellation factor is not present) when

the emergency stop is reset.

There must be a minimum interval of 1 second after an

emergency stop is actuated before it is reset. The home-

return completion status of incremental-encoder axes will

be retained.

11 Enable switch

(deadman/enable switch)

recovery type

0

0 ~ 2

0: Abort operations/programs

1: Recovery after reset

2: Operation continued (Only during automatic operation.

* Operation commands from the PC/TP will be aborted on

the PC/TP side.)