Part 1 Installation

(2) Variable monitor

The contents of global integer variables can be displayed on the panel window.

Positive integers of 1 to 999 can be displayed.

Parameter settings

Other parameter No. 49 = 2

Other parameter No. 50 = Variable number of the global integer variable to be monitored

When data is written to the flash ROM or a software reset (restart) is executed after the parameter values

have been input, the panel window will show the content of the global integer variable, instead of “ready

status” or “program run number.” The far-left segment digit should read “U.”

Display example)