IAI America ASEL User Manual

Page 179

Advertising
background image

Part 2 Programs

Chapter 3 Explanation of Commands

157

Part 2 Programs

z

DIS (Set division distance at spline movement)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,

declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional

Optional

DIS

Distance Prohibited

CP

[Function] Set a division distance for the interpolation implemented by a PSPL (move along spline)

command.

When a PSPL command is executed, a passing point will be calculated at each distance set

here and the calculated passing points will be used as interpolation points.

If the distance is set to “0,” an appropriate division distance will be calculated automatically so

that the actuator will operate at the set speed

The distance is input in mm.

(Note)

If a PSPL command is executed without setting a distance with a DIS command, the default

value registered in “All-axis parameter No. 31, Default division distance” will be used.

[Example]

DIS

10

Set the division distance to 10 mm.

Interpolation points

Division distance

Advertising