1.2 I/O Function Lists
(1) Input Function List

Input function

specification value Function name

Remarks

0

General-purpose input

1

Program start signal (BCD) (ON

edge)

Specify a BCD program number using the ports to which start-program number

specification bits x (input function specification values 9 through 15) are assigned.

* To ensure starting of the program, keep these bits ON for at least 100 msec.

* The following input functions cannot be assigned at the same time:

• Program start signal (BCD) (input function specification value = 1)

• Program start signal (BIN) (input function specification value = 2)

2

Program start signal (BIN) (ON

edge)

Specify a binary program number using the ports to which start-program number

specification bits x (input function specification values 9 through 15) are assigned.

* To ensure starting of the program, keep these bits ON for at least 100 msec.

* The following input functions cannot be assigned at the same time:

• Program start signal (BCD) (input function specification value = 1)

• Program start signal (BIN) (input function specification value = 2)

3

Soft reset signal (ON for 1

second)

If the emergency-stop recovery type is set to “Operation continued,” enable the soft reset

signal (to ensure the specified operation cancellation method will work.)

4

Servo ON

ON edge: Same as the all-valid-axes servo ON command

OFF edge: Same as the all-valid-axes servo OFF command (an interval of at least 1.5

seconds is required).

* The signal must be input when the actuator is not operating.

5

Auto-start program start signal

ON edge: Start the program

OFF edge: Abort all operations/programs (excluding the I/O processing program at

operation/program abort)

* Turn ON the signal for at least 100 msec to ensure starting of the program.

6

Soft interlock for all servo axes

(OFF level)

Effective when the servo OFF command is not active. Operations will be put on hold if the

interlock signal is input during auto operation. Operations will be aborted if the interlock

signal is input during non-auto operation.

7

Operation-pause reset signal

(ON edge)

8

Operation pause signal (OFF

level)

Effective only during auto operation.

* Pause is reset using the operation-pause reset signal.

9

Start-program number

specification bit 1 (least

significant bit)

* Start-program number specification bits x (input function setting values 9 through 15)

cannot be assigned discontinuously from the LSB or in descending order from the LSB

(port numbers are not considered). Program No. 1 (BIN or BCD)

10

Start-program number

specification bit 2

(Same as “Input function specification value = 9”) Program No. 2 (BIN or BCD)

11

Start-program number

specification bit 3

(Same as “Input function specification value = 9”) Program No. 4 (BIN or BCD)

12

Start-program number

specification bit 4

(Same as “Input function specification value = 9”) Program No. 8 (BIN or BCD)

13

Start-program number

specification bit 5

(Same as “Input function specification value = 9”) Program No. 16 (BIN) or 10 (BCD)

14

Start-program number

specification bit 6

(Same as “Input function specification value = 9”) Program No. 32 (BIN) or 20 (BCD)

15

Start-program number

specification bit 7

(Same as “Input function specification value = 9”) Program No. 64 (BIN) or 40 (BCD)

16

Error reset (ON edge)

17

Drive-source cutoff reset input

(ON edge) (Effective when the

problem factor has been

removed)

Drive-source cutoff control is not available for axes whose motor-drive power source is not

installed in this controller, or axes whose drive-source cutoff circuit is not controlled by this

controller.

18

Home return command signal

for all valid axes (ON edge)

The servo must be turned on first (Input function specification value = 4, axis-specific

parameter No. 13)

19

Home return command signal

for all incremental axes (ON

edge)

The servo must be turned on first (Input function specification value = 4, axis-specific

parameter No. 13)

20

PC/TP-servo movement

command acceptance

permission input

* Caution: Ineffective once operation is started.

21

Remote-mode control input

Is the specified DI is ON or the AUTO/MANU switch is set to “MANU,” the system mode

will become MANU.

* Debug filter is disabled on the remote-mode control input port.

22

Axis 1 forced brake-release

input

When the applicable port turns ON, the brake will be unlocked forcibly (pay attention to

falling load).

* Brake release of the synchronized slave axis conforms to brake release of the

synchronized master axis.

23

Axis 2 forced brake-release

input

When the applicable port turns ON, the brake will be unlocked forcibly (pay attention to

falling load).

* Brake release of the synchronized slave axis conforms to brake release of the

synchronized master axis.

24 ~ 27

For future expansion