Part 2 Programs

Chapter 3 Explanation of Commands

148

Part 2 Programs

z

DCL (Set deceleration)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,

declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional

Optional

DCL

Deceleration Prohibited

CP

[Function] Set the travel deceleration of the actuator.

The maximum deceleration will vary depending on the load and model of the actuator

connected.

The deceleration is set in G and may include up to two decimal places.

(Note)

If the position data contains no deceleration AND deceleration is not set by a DCL command,

the actuator will move based on the default value set in “All-axis parameter No. 12, Default

deceleration.”

A DCL command cannot be used with CIR and ARC commands.

[Example]

DCL

0.3

Set the deceleration to 0.3 G.

(Note)

Setting a deceleration exceeding the specified range for the actuator may generate an error.

It may also result in a failure or shorter product life.