IAI America ASEL User Manual

Page 375

Advertising
background image

Appendix

Parameter Utilization

353

Appendix

Example 1)

How to set input port No. 5 as an input to forcibly release the brake for axis 1

Change the input function specification value of I/O parameter No. 35, which corresponds to input port No.

5, to “22” (Axis 1 forced brake-release input).

I/O parameter No. 35 = 22

Example 2)

How to set output port No. 307 as a servo-ON status output for axis 1

Change the output function specification value of I/O parameter No. 53, which corresponds to output port

No. 307, to “24” (Axis 1 servo-ON status output).

I/O parameter No. 53 = 24

Example 3)

How to set input port Nos. 21 and 22 as general-purpose inputs

Change the input function specification values of I/O parameter Nos. 256 and 257, which correspond to

input port Nos. 21 and 22, respectively, to “0” (General-purpose input).

I/O parameter No. 256 = 0

I/O parameter No. 257 = 0

If the above parameter changes are made from their factory settings, the start-program number

specification bits will change to the five bits represented by input port Nos. 16 through 20. The range of

program numbers that can be specified will become 1 to 19.