Appendix

List of Parameters

382

Appendix

(2) Output Function List

Output function

specification value Function name

Remarks

0

General-purpose output

1

Operation-cancellation level or

higher error output (ON)

* The following output functions cannot be assigned at the same time:

• Operation-cancellation level or higher alarm output (ON) (Output function

specification value = 1)

• Operation-cancellation level or higher alarm output (OFF) (Output function

specification value = 2)

• Operation-cancellation level or higher alarm + emergency stop output (ON) (Output

function specification value = 3)

• Operation-cancellation level or higher alarm + emergency stop output (OFF)

(Output function specification value = 4)

2

Operation-cancellation level or

higher error output (OFF)

(Same as “Output function specification value = 1”)

3

Operation-cancellation level or

higher error + emergency stop

output (ON)

(Same as “Output function specification value = 1”)

4

Operation-cancellation level or

higher error + emergency stop

output (OFF)

(Same as “Output function specification value = 1”)

5

READY output (PIO trigger program

operation enabled)

* The following output functions cannot be assigned at the same time:

• READY output (PIO trigger program operation enabled) (Output function

specification value = 5)

• READY output (PIO trigger program operation enabled AND absence of

operation-cancellation level or higher error) (Output function specification value =

6)

• READY output (PIO trigger program operation enabled AND absence of cold-start

level or higher error) (Output function specification value = 7)

6

READY output (PIO trigger program

operation enabled AND absence of

operation-cancellation level or higher

error)

(Same as “Output function specification value = 5”)

7

READY output (PIO trigger program

operation enabled AND absence of

cold-start level or higher error)

(Same as “Output function specification value = 5”)

8

Emergency stop output (ON)

* The following output functions cannot be assigned at the same time:

• Emergency stop output (ON) (Output function specification value = 8)

• Emergency stop output (OFF) (Output function specification value = 9)

9

Emergency stop output (OFF)

(Same as “Output function specification value = 8”)

10

AUTO mode output

11

Auto operation status output

(Other parameter No. 12)

12

All-valid-axes home (= 0) output

* To move the absolute-encoder axis to coordinate 0 or the preset home coordinate,

use a MOVP command instead of a HOME command.

13

All-valid-axes home return complete

(coordinate confirmed) output

* To move the absolute-encoder axis to coordinate 0 or the preset home coordinate,

use a MOVP command instead of a HOME command.

14

All-valid-axes preset home

coordinate output

* To move the absolute-encoder axis to coordinate 0 or the preset home coordinate,

use a MOVP command instead of a HOME command.

15

Voltage-low warning output for

system-memory backup battery

16

Voltage-low warning output for

absolute-data backup battery

All axes are checked by the OR gate. Once an abnormal level has been detected, the

signal will remain ON until a power ON reset or software reset is performed.

17

Drive-source cutoff (SDN)

notification output

The output port will turn OFF when the drive source is cut off.

(* Caution: This notification output is implemented only by software means.)

18

For future expansion

19

For future expansion

20 ~ 23

For future expansion

24

Axis 1 servo-ON status output

25

Axis 2 servo-ON status output

26 ~ 29

For future expansion

The following assignments are prohibited:

• Assign a specification value not included in the I/O function lists.

• Assign the same input function specification value, which is not for general-purpose input, to multiple input ports.

• Assign the same output function specification value, which is not for general-purpose output, to multiple output ports.

(For the conditions associated with each specification value, refer to the Remarks field of the applicable item.)

If a prohibited assignment is set, an error “I/O function assignment error” will generate and all input ports and output ports will

become general-purpose inputs and general -purpose outputs, respectively.

* In the positioner mode, input and output function assignments are ignored. Each function will follow the corresponding specification

in the positioner mode.