Part 2 Programs

Chapter 3 Explanation of Commands

158

Part 2 Programs

z

POTP (Set PATH output type)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,

declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional

Optional

POTP

0 or 1

Prohibited

CP

[Function] Set the output type in the output field to be used when a PATH or PSPL command is

executed.

When a PATH or PSPL command is executed, the output will operate as follows in

accordance with the setting of the POTP command.

(1) POTP [Operand 1] = 0 (ON upon completion of operation)

The output port or flag will turn ON upon completion of operation.

(2) POTP [Operand 1] = 1 (Increment and output on approaching each position; ON upon

completion of operation for the last position)

During PATH or PSPL operation, the output port number or flag number specified in the

output field will be incremented and turned ON when each specified position approaches.

At the last position, however, the output will turn ON upon completion of operation. This

setting provides a rough guide for output in sequence control.

(Note 1)

The default value of POTP, before it is set, is “0.”

(Note 2)

If POTP = 1 and there is no valid data at the specified position, the output number will be

incremented but the output will not turn ON. (The output number will be incremented

regardless of the size of position numbers specified in operands 1 and 2 in a PATH or PSPL

command.)

[Example]

POTP 1

PATH 1

5

300

Turn ON output port Nos. 300 through 304 sequentially

each time a specified position approaches during a

pass movement from position Nos. 1 through 5, starting

from the first position.

Position No. 1

No. 3

No. 5

Turn ON output port 300.

Position origin

No. 2

No. 4

Turn ON output port 301.

Turn ON output port 303.

Turn ON output port 304.

Turn ON output port 302.