IAI America ASEL User Manual

Page 60

Advertising
background image

Chapter 3 Installation and W

iring

Part 1 Installation

38

Part 1 Installation

6.5.2

PNP Specification

(1) Input part

External Input Specifications (PNP Specification)

Item

Specification

Input voltage

24 VDC r10%

Input current

7 mA per circuit

ON/OFF voltage

ON voltage --- 8 VDC max.

OFF voltage --- 19 VDC min.

Insulation method

Photocoupler insulation

External devices

[1] No-voltage contact (minimum load of approx. 5 VDC/1 mA)

[2] Photoelectric/proximity sensor (PNP type)

[3] Sequencer transistor output (open-collector type)

[4] Sequencer contact output (minimum load of approx. 5 VDC/1 mA)

[Input circuit]

* N: I/O interface pin No. 17B

Caution

If a non-contact circuit is connected externally, malfunction may result from leakage

current. Use a circuit in which leakage current in a switch-off state does not exceed 1

mA.



ASEL controller’s input signal

At the default settings, the system recognizes the ON/OFF durations of input signals if they

are approx. 4 msec or longer. The ON/OFF duration settings can also be changed using I/O

parameter No. 20 (input filtering frequency).

In

te

rn

al

c

irc

ui

t

Input terminal

External power

supply 24 VDC 10%

N*

560 :

3.3 K:

ON duration

OFF duration

+

-

Advertising