IAI America ASEL User Manual

Page 138

Advertising
background image

Part 2 Programs

Chapter 3 Explanation of Commands

116

Part 2 Programs

z

INB (Read I/O, flag as BCD)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,

declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional

Optional

INB

I/O, flag BCD digits

CC

[Function] Read the I/O ports or flags from the one specified in operand 1 for the number of digits

specified in operand 2, to variable 99 as a BCD.

15

14

13

12

11

10

9

8

Input port number

ON OFF OFF OFF OFF

ON

OFF

ON

85

Variable 99

(Note 1)

A maximum of eight digits (32 bits) can be input.

(Note 2)

The number of I/O ports and flags that can be used is 4 x n (digits).

(Note 3)

The read data format can be changed using a FMIO command (refer to the section on FMIO

command).

[Example 1]

INB

8

2

Read input ports 8 through 15, to variable 99 as a

BCD.

[Example 2]

LET

1

8

Assign 8 to variable 1.

LET

2

2

Assign 2 to variable 2.

INB

*1

*2

Read the input ports from the content of variable 1

(input port 8) for the content of variable 2 (two digits)

(until input port 15), to variable 99 as a BCD.

Upper digit

Lower digit

8

5