IAI America ASEL User Manual

Page 337

Advertising
background image

Part 3 Positioner Mode

Chapter 3 Product Switching Mode

315

Part 3 Positioner Mode

5.2

Home Return

Timings associated with home-return operation are illustrated below.

Timing Chart of Home-return Operation (Standard Positioner Mode)

Perform home-return operation by following the procedure explained below.

* Before commencing the procedure, confirm that the ready output signal and alarm output signal are ON.

[1] Turn ON the servo ON input signal.

[2] Confirm that the servo-ON status output signal is

ON.

[3] Turn ON the home-return input signal.

[4] Confirm that the positioning complete output signal is

OFF.

[5] Turn OFF the home-return input signal.

[6] Confirm that the home-return complete output signal

is ON. Home return is now completed.

*Pause and *cancellation inputs are contact-B input signals (always ON), so keep these signals ON while home return

is in progress.

To initiate home return using the home-return signal input, the servo ON input signal must be ON. These operation

commands will not be accepted if the servo ON input signal is OFF. Note, however, that only the commands will be

ignored and no error will generate.

With the 2-axis specification, the controller has been configured at the factory so that the two axes will start home

return simultaneously.

You can cause either axis to start home return earlier than the other axis by changing the applicable parameter setting.

Specifically, change the setting in axis-specific parameter No. 13, “SIO/PIO home-return order” so that the parameter

value for the axis number corresponding to the axis for which you want to complete home return first, will become

smaller than the parameter value for the other axis number.

Example)

Cause axis 1 to perform home return after axis 2 has completed home return, set “1” for axis 1 and “0” for

axis 2 in axis-specific parameter No. 13.

Input

Output

Start

Home return

Servo ON

Alarm

Ready

Positioning complete

Home return complete

Servo ON status

Home return in progress

Warning : Turning the servo ON near the mechanical end may disturb the magnetic pole phase

detection, and may cause the magnetic pole unconfirmed error or the magnetic pole

detection error.

Put the slider or rod away from the mechanical end when turning the servo ON.